China wholesale Type B RCD & RCBO – 100A AC 100mA 4pole 10KA Type B RCD DC 6mA EV RCCB Circuit Breaker – Mida
China wholesale Type B RCD & RCBO – 100A AC 100mA 4pole 10KA Type B RCD DC 6mA EV RCCB Circuit Breaker – Mida Detail:
Residual Circuit Breaker (RCD)
MIDA RCD product line includes Residual-current devices (RCD), Earth leakage current circuit breakers (ELCB), RCD devices with overcurrent protection (RCBO), and the full range of leakage current protection circuits breakers.
What is a Circuit Breaker?
A circuit breaker is just one of the electrical devices that functions mechanically to safeguard an electrical current from an overload or short circuit harm. Its primary purpose is to stop the flow of current when it identifies a defect. Unlike switchgear, which only works once before being replaced, you may reconfigure a circuit breaker (manually and automatically) to return to its standard functionality.
Circuit breakers come in various sizes, ranging from tiny devices that safeguard low-current circuits or single domestic appliances to massive power supply systems that protect high-voltage circuits that supply an entire community. OCPD (Over Current Protection Device) is a common acronym for the fundamental operation of a fuse box, or fuses, as an automated mechanism of eliminating power from a flawed system.
| Item | Type B RCD / Type B RCCB |
| Product Model | EKL6-100B |
| Type | B Type |
| Rated Current | 16A , 25A , 32A , 40A , 63A , 80A ,100A |
| Poles | 2Pole ( 1P+N ) , 4Pole ( 3P+N ) |
| Rated voltage Ue | 2Pole: 240V ~ , 4Pole: 415V~ |
| Insulation Voltage | 500V |
| Rated frequency | 50/60Hz |
| Rated residual operation current(I n) | 30mA , 100mA , 300mA |
| Short-circuit current Inc= I c | 10000A |
| SCPD fuse | 10000 |
| Break time under I n | ≤0.1s |
| Dielectric test voltage at ind.Freq. for 1min | 2.5kV |
| Electrical life | 2,000 Cycles |
| Mechanical life | 4,000 Cycles |
| Protection Degree | IP20 |
| Ambient temperature | -5℃ upto +40℃ |
| Storage temperature | -25℃ upto +70℃ |
| Terminal connection type | Cable/Pin type busbar U-type busbar |
| Terminal size top/bottom for cable | 25mm² 18-3AWG |
| Terminal size top/bottom for busbar | 25mm² 18-3AWG |
| Tightening torque | 2.5Nm 22In-Ibs |
| Mounting | On DIN rail EN60715(35mm) by means of fast clip device |
| Connection | From top and bottom |
| Standard | IEC 61008-1:2010 EN 61008-1:2012 IEC 62423:2009 EN 62423:2012 |
Deliver,Shipping And Serving of the EV Portable AC Charging Waterproof Cable
1) .Delivery time
Within 20 ~25 business day after the receipt of deposit.
2).Packaging
Export cartons, pallets or wood case for electric parts and accessories.
3).Transportation
By air or by sea.
4).Payment terms
Wire Transfer, Paypal. We can accept 50%T/T in advance, the balance paid before shipment.
Product detail pictures:
Related Product Guide:
Fast and superior quotations, informed advisers to help you choose the correct merchandise that suits all your requirements, a short generation time, responsible quality control and different services for paying and shipping affairs for China wholesale Type B RCD & RCBO – 100A AC 100mA 4pole 10KA Type B RCD DC 6mA EV RCCB Circuit Breaker – Mida , The product will supply to all over the world, such as: Ecuador, Sheffield, luzern, Strict quality control is executed in each link of the whole production process.We sincerely hope to establish the friendly and mutual-beneficial cooperation with you. Based on high quality products and perfect pre-sales /after-sales service is our idea, some clients had cooperated with us for more than 5 years.
Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.











